{"id":4898,"date":"2017-11-28T11:40:09","date_gmt":"2017-11-28T00:40:09","guid":{"rendered":"https:\/\/www.computationalfluiddynamics.com.au\/?p=2788"},"modified":"2017-11-28T11:40:09","modified_gmt":"2017-11-28T00:40:09","slug":"guest-blog-adra-group-increasing-pump-system-performance","status":"publish","type":"post","link":"https:\/\/www.leapaust.com.au\/blog\/cfd\/guest-blog-adra-group-increasing-pump-system-performance\/","title":{"rendered":"Guest Blog by Adra Group: Increasing Pump System Performance through CFD"},"content":{"rendered":"<div id=\"bsf_rt_marker\"><\/div><blockquote><p><strong><em><a href=\"http:\/\/www.adragroup.com.au\/\" target=\"_blank\" rel=\"noopener noreferrer\"><img decoding=\"async\" class=\"alignright wp-image-2806\" src=\"https:\/\/www.leapaust.com.au\/blog\/wp-content\/uploads\/2017\/11\/EDR-001-Adra-Group-logo-w-tagline-on-white-300x212.jpg\" alt=\"\" width=\"100\" height=\"71\" \/><\/a>In this guest post, <\/em><em><a href=\"http:\/\/www.adragroup.com.au\/\" target=\"_blank\" rel=\"noopener noreferrer\">Adra Group <\/a><\/em><em>explains how <a href=\"https:\/\/www.leapaust.com.au\/ansys-fluids\/\" target=\"_blank\" rel=\"noopener noreferrer\">ANSYS CFD software<\/a> has assisted them to provide even greater value to their clients, beyond the capabilities of their traditional FEA tools.<\/em><\/strong><\/p><\/blockquote>\n<p><a href=\"http:\/\/www.adragroup.com.au\/\" target=\"_blank\" rel=\"noopener noreferrer\">Adra Group<\/a> were approached by Hydro Australia, the largest independent pump rebuilder in the world, to assist them with an investigation into the severe noise and vibration issues encountered at a site, which was also running inefficiently leading to high operating costs.<\/p>\n<p>Hydro Australia singled out the vertical canister pumps as the source of the problem.<\/p>\n<p><a href=\"https:\/\/www.leapaust.com.au\/blog\/wp-content\/uploads\/2017\/11\/Adra-fig1.png\"><img fetchpriority=\"high\" decoding=\"async\" class=\"aligncenter wp-image-2789 size-large\" src=\"https:\/\/www.leapaust.com.au\/blog\/wp-content\/uploads\/2017\/11\/Adra-fig1-1024x453.png\" alt=\"Left: 3D flow velocity streamlines into pump canister; Right: Cross-section (X-Y view) schematic of pump-canister assembly\" width=\"838\" height=\"371\" \/><\/a><\/p>\n<p>However, they could not be certain of the exact problem without disassembling and inspecting the pump and there were significant costs associated with stopping production.<\/p>\n<p><a href=\"https:\/\/www.leapaust.com.au\/blog\/wp-content\/uploads\/2017\/11\/Adra-fig2a.png\"><img decoding=\"async\" class=\"aligncenter size-large wp-image-2805\" src=\"https:\/\/www.leapaust.com.au\/blog\/wp-content\/uploads\/2017\/11\/Adra-fig2a-1024x724.png\" alt=\"\" width=\"838\" height=\"592\" \/><\/a><\/p>\n<p>Adra Group were consulted to provide an in-depth view into the canister pump by using Computational Fluid Dynamics (CFD) to simulate the real-life conditions and behaviour of the pump system.<\/p>\n<p>&nbsp;<\/p>\n<p>ANSYS CFD was able to provide accurate, quantitative information and visualisation on the internal behaviour of the canister pump in its operating environment.<a href=\"https:\/\/www.leapaust.com.au\/blog\/wp-content\/uploads\/2017\/11\/Adra-fig4.png\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-2792 size-large\" src=\"https:\/\/www.leapaust.com.au\/blog\/wp-content\/uploads\/2017\/11\/Adra-fig4-1024x889.png\" alt=\"\" width=\"838\" height=\"728\" \/><\/a><\/p>\n<p>Adra Group was able to use ANSYS CFD to provide Hydro Australia with internal flow information and details that are virtually impossible to measure or visualise in real life. \u00a0The insight gained from this simulation provided not only the evidence Hydro Australia required to propose a solution, but an opportunity to demonstrate the implemented solution to their client prior to any work commencement and provide greater confidence in achieving a favourable outcome.<\/p>\n<p><a href=\"https:\/\/www.leapaust.com.au\/blog\/wp-content\/uploads\/2017\/11\/Adra-fig5.png\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-2793 size-large\" src=\"https:\/\/www.leapaust.com.au\/blog\/wp-content\/uploads\/2017\/11\/Adra-fig5-1024x982.png\" alt=\"\" width=\"838\" height=\"804\" \/><\/a><\/p>\n<p>Adra Group engineers worked closely with Hydro Australia experts to:<\/p>\n<ul>\n<li>Identify the exact source and location of the problem within the pump.\n<ul>\n<li>Flow into pump bell-mouth was non-uniform and biased causing high pressure losses and vibration.<\/li>\n<\/ul>\n<\/li>\n<li>Develop and trial various modifications to the pump internals within ANSYS CFD to determine the most clever &amp; practical solution.<\/li>\n<li>Verify and validate the effects of these changes.<\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<p>Using CFD, Adra Group and Hydro Australia were able to deliver the most cost-effective solution for the client, as well as piece of mind that the solution would be effective.<\/p>\n<p>&nbsp;<\/p>\n<h2><strong>About Adra Group<\/strong><\/h2>\n<p><a href=\"http:\/\/www.adragroup.com.au\/\" target=\"_blank\" rel=\"noopener noreferrer\"><img loading=\"lazy\" decoding=\"async\" class=\"alignleft wp-image-2806\" src=\"https:\/\/www.leapaust.com.au\/blog\/wp-content\/uploads\/2017\/11\/EDR-001-Adra-Group-logo-w-tagline-on-white-300x212.jpg\" alt=\"\" width=\"200\" height=\"141\" \/><\/a>Adra Group are a resourceful multidiscipline engineering company founded in 1991.\u00a0 Today, with over 40 fulltime staff based around Australia, Adra Group continues to grow in both size and capability, providing an unmatched value proposition.\u00a0 We deliver clever, practical solutions for a national client base across a broad range of industries.<\/p>\n<p><strong>For more info, <a href=\"http:\/\/www.adragroup.com.au\" target=\"_blank\" rel=\"noopener noreferrer\">visit the Adra Group website<\/a><\/strong>\u00a0(formerly <strong>EDR\/Plant Performance<\/strong>) or phone\u00a0Victoria (Head Office) +61 3 5173 7600 or Perth\u00a0+61 8 9479 5253<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n","protected":false},"excerpt":{"rendered":"<p>In a guest post, Adra Group explains how ANSYS CFD was used to assist Hydro Australia to identify and resolve non-uniform flow issues (into vertical canister pumps) which was causing severe noise and vibration issues and high operating costs.<\/p>\n","protected":false},"author":3,"featured_media":4398,"comment_status":"open","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"neve_meta_sidebar":"","neve_meta_container":"","neve_meta_enable_content_width":"","neve_meta_content_width":0,"neve_meta_title_alignment":"","neve_meta_author_avatar":"","neve_post_elements_order":"","neve_meta_disable_header":"","neve_meta_disable_footer":"","neve_meta_disable_title":"","neve_meta_reading_time":"","footnotes":""},"categories":[323],"tags":[174,395,407,434,451],"class_list":["post-4898","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-cfd","tag-ansys-cfd","tag-cfd-modelling-of-turbulent-flows","tag-design-and-testing","tag-guest-post","tag-minerals-and-process-industries"],"_links":{"self":[{"href":"https:\/\/www.leapaust.com.au\/blog\/wp-json\/wp\/v2\/posts\/4898","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.leapaust.com.au\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.leapaust.com.au\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.leapaust.com.au\/blog\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/www.leapaust.com.au\/blog\/wp-json\/wp\/v2\/comments?post=4898"}],"version-history":[{"count":0,"href":"https:\/\/www.leapaust.com.au\/blog\/wp-json\/wp\/v2\/posts\/4898\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.leapaust.com.au\/blog\/wp-json\/wp\/v2\/media\/4398"}],"wp:attachment":[{"href":"https:\/\/www.leapaust.com.au\/blog\/wp-json\/wp\/v2\/media?parent=4898"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.leapaust.com.au\/blog\/wp-json\/wp\/v2\/categories?post=4898"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.leapaust.com.au\/blog\/wp-json\/wp\/v2\/tags?post=4898"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}